What was found
MAIN DECK AT STATION 1661 FLOOR BEAM UPPER SURFACE CORRODED. REMOVED FLOOR BEAM, FABRICATED NEW PART FROM, BAC 1518-338A, LOCATED AND DRILLED IAW DRAWING 146N5110-6, PRIMED IAW-AMM-51-21-10, APPLIED TOP COAT IAW-AMM-51-21-10, MARKED AS FX-146N5110-6, INSTALLED IAW-SRM-51-40-02 AND DRWG 146N5110-6, AT STA 1661, CAT "A" MAJOR REPAIR.