What was found
MAIN DECK CARGO DOOR LOWER FRAME SUPPORT FITTING DAMAGED. NR 1 HOLE REAMED TO 0.562 INCHES. HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION CARRIED FOUND CRACK INDICATION STILL EXIST, APPROXIMATELY 0.040 INCH. SUPPORT FITTING REMOVED AND REPLACED IAW SRM 51-33-01 REVISION 53. REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100 REVISION 119