What was found
MAIN DECK CARGO FLOORBEAM UPPER TEE HAS NICKS & SCRATCHES AT BS 365. FOUND TO BE OUT OF LIMITS. INSTALLED NEW FLOORBEAM TEE IAW SRM 51-40-02 AND DWG 141N5112. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK CARGO FLOORBEAM UPPER TEE HAS NICKS & SCRATCHES AT BS 365. FOUND TO BE OUT OF LIMITS. INSTALLED NEW FLOORBEAM TEE IAW SRM 51-40-02 AND DWG 141N5112. MAJOR REPAIR.