What was found
MAIN DECK CABIN FLOORBEAM UPPER TEE AT BS 345 HAS AREAS WITH NICKS, SCRATCHES & CORROSION. AFTER REWORK, FOUND TO BE OUT OF LIMITS. REMOVED FLOORBEAM TEE IAW SRM 51-40-02. LOCATED, DRILLED IAW SRM 51-40-02 & DRAWING 141N5111. INSTALLED FLOORBEAM TEE IAW SRM 51-40-02 & DRAWING 141N5111. REPAIR IS CLASSIFIED AS CATERGORY A MAJOR.