What was found
CABIN STATION 377 - 395 L1 DOOR LOWER SILL WEB FOUND CORROSION AT LOWER SURFACE. REMOVED IAW SRM 51-10-02 REV 110. REWORKED AREA EVALUATED MATERIAL THICKNESS, REMOVED 0.018 INCHES FOUND EXCEED 10 % LIMIT IAW SRM 53-10-15, ALLOWANCE DAMAGE 1 FIG 101 REV 110. L1 DOOR LOWER SILL WEB REMOVED IAW SRM 51-40-02 REV 111. L1 DOOR LOWER SILL WEB FABRICATED & INSTALLED IAW DWG 141N8322 SHTTE 1 REV K & 141N8322 SHT 2 REV F.