As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NOTED VERTICAL TIP PANEL ATTACH ANGLES, BOTH LT & RT SIDES HAS NUMEROUS ELONGATED HOLES AT VERTICAL STAB TIP STRUCTURE. FOUND TO BE OUT OF LIMITS IAW DWG 172N3014 SHT 1 REV D. REMOVED ANGLES IAW SRM 51-40-02. FABRICATED NEW ANGLES IAW DWG 172N3014 & SRM 51-40-05. INSTALLED ANGLE IAW SRM 51-40-02. MAJOR REPAIR.