What was found
AT EMPENNAGE AREA BETWEEN FRAME 86 & FRAME 87, STRINGER 34L UPPER ANGLE CRACKED. REMOVED WEB & UPPER ANGLE IAW SRM 51-40-21, NO DAMAGE ON WEB NOTED. FABRICATED NEW ANGLE IAW DRAWING 53986751, MAT 2024-T3, 032C BATCH 0002526114. LOCATED & DRILLED, TREATED & PRIMED, APPLIED TOPCOAT TO NEW ANGLE IAW SRM 51-40-44, 51-21-10, 51-75-10. PART MARKED ANGLE IAW 7-0-1001. INSTALLED NEW ANGLE TO WEB & INSTALLED WEB IAW SRM 51-40-21. APPLIED TOPCOAT TO FASTENERS IAW SRM 51-75-10.