What was found
FORWARD CARGO BAY DOOR CUTOUT FITTING CORRODED BETWEEN FRAMES 23 - 24, STRINGERS 49R - 54L. CORROSION REMOVED AND FOUND OUT OF LIMITS. REPAIRED IAW SRM 53-13-12-201 PARA 6B(6) & PARA6B(4).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO BAY DOOR CUTOUT FITTING CORRODED BETWEEN FRAMES 23 - 24, STRINGERS 49R - 54L. CORROSION REMOVED AND FOUND OUT OF LIMITS. REPAIRED IAW SRM 53-13-12-201 PARA 6B(6) & PARA6B(4).