What was found
CABIN BS 660, STRINGER 17R INBD CHORD CORRODED. REMOVED DAMAGE & CHECKED LIMITS, ORIGINAL MATERIAL .070, LOSS OF MATERIAL .020, REMAINING MATERIAL IS .050. FOUND TO BE OUT OF LIMITS IAW-53-30-13 FIG 101 DETAIL VIII. R & R CREASE BEAM CHORD RT SIDE STATION 450 TO 665, RBL 64, IAW DWG 143N5520 & SRM-51-40-02.