What was found
DURING OPEN HOLE HIGH FREQUENCY EDDY CURRENT INSPECTION, HFEC, AT LT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS 683.4 & STATION XORS 713.6 FOUND FOUR EACH FASTENER HOLES 11, 15, 27 & 36 WITH CRACK INDICATIONS. REPAIRED AS PER SRM 57-20-02 FIGURE 201 REPAIR 5 REVISION 53. REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100.