What was found
AFT CARGO SPLICES & STRINGER BOTH HAVE CORROSION STATION 1460, STRINGER 22L. REMOVED CORROSION IAW SRM 51-10-02 FOUND TO BE OUT OF LIMITS, STRINGER ONLY, IAW SRM 53-00-03 FIG 201, REPAIR NR 2 AT STATION 1430 - 1460, STRINGER 22L.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO SPLICES & STRINGER BOTH HAVE CORROSION STATION 1460, STRINGER 22L. REMOVED CORROSION IAW SRM 51-10-02 FOUND TO BE OUT OF LIMITS, STRINGER ONLY, IAW SRM 53-00-03 FIG 201, REPAIR NR 2 AT STATION 1430 - 1460, STRINGER 22L.