What was found
FLOORBEAM AT FS 1640 RBL-LBL 65, HAS AREAS OF CORROSION ON TOP TEE. REMOVED CORROSION ON FLOORBEAM. FOUND OUT OF LIMITS, REMOVED FLOORBEAM , FABRICATED NEW FLOORBEAM. INSTALLED FLOORBEAM IAW DWG 146N5136 & SRM 51-40-02. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT FS 1640 RBL-LBL 65, HAS AREAS OF CORROSION ON TOP TEE. REMOVED CORROSION ON FLOORBEAM. FOUND OUT OF LIMITS, REMOVED FLOORBEAM , FABRICATED NEW FLOORBEAM. INSTALLED FLOORBEAM IAW DWG 146N5136 & SRM 51-40-02. MAJOR REPAIR.