What was found
NUMBER 1 PYLON UPPER INBD HOLE OF VERTICAL FLANGE OF STRUT TO DIAGONAL BRACE FITTING HAS A CRACK INDICATION. ACCOMPLISHED EA F-5450-T0306349, NACELLES & PYLON, PYLONS STRUCTURES DEVIATION TO EO F-5450-7-5006, DUE TO CRACK IN BULKHEAD AT BRACE FITTING MOUNT HOLE. MAJOR REPAIR CAT A.