What was found
AFT CARGO COMPARTMENT STATION 1540 STRINGER 24L FRAME SPLICE HAS CORROSION. REMOVED FRAME SPLICE STATION 1540 DUE TO ELONGATED HOLES, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07 FIG 101 DET I. R & R FRAME SPLICE IAW SRM 51-40-05 & DWG 146N1042. REMOVED CORROSION, FOUND TO BE IN LIMITS IAW SRM 53-00-07 FIG 101 DET I.