What was found
FLOORBEAM TEE BS 1640 RBL 44 - 60 CORRODED ON THE BOTTOM SIDE OF THE TOP FLANGE. REMOVED CORROSION IAW SRM 51-10-02, & FOUND TO BE OUT OF LIMITS. R & R FLOORBEAM TEE AT BS 1640 IAW SRM 51-40-02, DWG 146N5089.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM TEE BS 1640 RBL 44 - 60 CORRODED ON THE BOTTOM SIDE OF THE TOP FLANGE. REMOVED CORROSION IAW SRM 51-10-02, & FOUND TO BE OUT OF LIMITS. R & R FLOORBEAM TEE AT BS 1640 IAW SRM 51-40-02, DWG 146N5089.