What was found
LEFT SIDEWALL FRAME HAS DENT AT STATION 1400, NEAR STRINGER 25L. EVALUATED FRAME STATION 1400, LT SIDE & DENTS NOT ALLOWED ON FLANGE IAW SRM 53-00-07, FIG 101, DETAIL II. R & R FRAME IAW SRM 51-40-02 & DWG 146N1011. FRAME WAS RECEIVED ON TRAVELER T14 1063426, STATION 1400, STRINGER 25L - STRINGER 27R. MAJOR REPAIR.