What was found
R2 DOOR FWD FRAME, UPPER HINGE CUT OUT EDGE NICKED. CRACK WAS FOUND OUT OF LIMITS IAW SRM 52-10-02, DETAIL IX, FIG. 101. LOCATED AND DRILLED AND INSTALLED REPAIR IAW SRM 52-10-02, FIG. 201, REPAIR 1. COMPLIED WITH EA F-5210-T0308334, PT. 1. MAJOR REPAIR.