What was found
ON WALK AROUND FOUND SUSPECTED CRACK ON RIGHT WING INBD CORNER OF FUEL PANEL ON LOWER WING. COMPLIED WITH HFEC INSPECTION OF ABOVE NOTED AREA IAW SPM 06-10-01.001 CRACK NOTED. RUNNING FROM CORNER OUT PAST FIRST RIVET TO SECOND RIVET APPROXIMATELY 2 1/2 INCHES LONG. RIGHT WING REFULEING DOOR & LOWER SKIN PANEL REMOVED IAW SMP TO FOM ACCESS & REPAIR OF CRACK. DISPLACED TERMINAL STRIPS STRINGER 3 - 688 & STRINGER 3 - 690 FROM RT WING AT WS 610.840 TO FOM SHEETMETAL REPAIR. DISPLACED TERM STRIP ZIPTIED TO ADJACENT STRUCTURE. REMOVED DAMAGED AREA IAW SRM 57-10-00 VOLUME 1 FIGURE 68. RECEIVED FINAL FORM 8100-9 & ACCOMPLISHED REPAIRS IAW EA 8-5710-T0308360.