What was found
LOWER FUSELAGE EXTERNAL SKIN SCRATCHED, LOCATION BETWEEN FRAME 66 & 67 FROM STRING 49 RT TO 52 RT. DURING PRELIMINARY INSPECTION WAS FOUND, BLEND OUT THE SCRATCHED ARE & MEASURE THE MAX DEPTH 0.036"X2.7"X1.7" DXLXW OVER ALLOWABLE LIMIT IAW AB6F SRM 53-17-12 & 53-10-12 DIAGRAM 101. DRILL OUT AFFECTED FASTENERS & CUT OUT THE DAMAGE SKIN LXW=2.7"X1.75". COMPLIED WITH AB6F SRM 53-10-12 PARAGRAPH 11. FABRICATED THE DOUBLER & INSTALL THE DOUBLER WITH RIVETS BY SEALANTS. COMPLIED WITH IIR 53-10-12-2-002-00 TABLE 205C.