What was found
RIGHT WING INBD FLAP OTBD AFT HINGE OTBD PIVOT LUG FOUND OUT OF LIMIT AFTER BUSHING REMOVAL. OVERSIZED BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-159871A PART 2 STEP 1 . REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100 REVISON 122.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT WING INBD FLAP OTBD AFT HINGE OTBD PIVOT LUG FOUND OUT OF LIMIT AFTER BUSHING REMOVAL. OVERSIZED BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-159871A PART 2 STEP 1 . REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100 REVISON 122.