What was found
DURING WALK AROUND, FOUND LT WING OTBD SLAT CUT OUT PANEL FWD LT CORNER, NR 5 SLAT CUT OUT PANEL CRACKED. PERFORMED HFEC INSPECTION IAW NDT SPM 06-10-01 & VERIFIED CRACK FROM EDGE TO RIVET HOLE. REMOVED CRACK IN SKIN IAW SRM. FABRICATED DOUBLER & FILLER IAW SRM. PERFORMED HFEC OF THE CUT OUT AREA IAW NDT SPM 93K0393 PART 6, NO CRACKS NOTED. TREATED & PRIMED FILLER & DOUBLER IAW SRM. INSTALLED FILLER & DOUBLER, SEALED & PAINTED IAW SRM.