As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FIVE EACH FASTENER HOLES 08, 28, 29, 30 & 31 FOUND CRACK INDICATIONS DURING OPEN HOLE HIGH FREQUENCY EDDY CURRENT INSPECTION AT LT WING LOWER SKIN ACCESS DOOR CUT OUT BETWEEN STATION XORS =690 & XORS=700. SKIN ACCESS DOOR CUTOUT REPAIRED AS PER SRM 57-20-02 FIGURE 201 REPAIR 5 REVISION 55. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 122.