What was found
FOUND FUSELAGE CTR SECTION LOWER FRAMES FITTINGS BASE. FITTING CRACK ABOUT 0.375 INCHES AT FRAME 46 POSITION. PERFORMED FRAME FEET MODIFICATION BTW STATION FRAME 41 & 46 IAW EO 6-5310-7-5015 01 PART 2. TITLE FUSELAGE CTR WING, FRAME, FRAME FEET, FRAME 41 THRU 46, STRINGER 35 THRU 37. REPAIR WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.