What was found
FOUND FUSELAGE CTR SECTION LOWER FRAMES FITTINGS BASE. FITTING CRACK ABOUT 0.500 INCHES AT FRAME 45. PERFORMED FRAME FEET MODIFICATION BTW STATION FRAME 41 & 46 IAW EO 6-5310-7-5015 01 PART 2. TITLE FUSELAGE, CTR WING, FRAME, FRAME FEET, FRAME 41 - 46, STRINGER 35 - 37. REPAIR WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.