AFT PIT BS 1520 STRINGER 21L FRAME INBD FLANGE DENTED. NO DENTS ALLOWED ON FREE FLANGE PER SRM 53-00-07, FIG. 101, FOUND OUT OF LIMITS PER SRM B757 53-00-07, FIG 101. REMOVED AND REPLACED FRAME IAW SRM 51-40-02 AND B757 DRAWING 146N1017, S26L - S26R. MAJOR REPAIR