What was found
FRAME FEET RT SIDE FRAME 46 FOUND CORRODED ANGLE WHILE ACCOMPLISHING EO 6-5310-7-5015 PT 2. FRAME 46 RT ANGLE CORRODED, BLENDED AREA IAW SRM 51-74-10 & OUT OF LIMITS IAW SRM 53-15-13, DIMENSIONS L=2.0 INCHES W=1.0 INCH D=0.035 INCHES. REMOVED ANGLE, FABRICATED NEW ANGLE ON T14 1093330, LOCATED & DRILLED. TREATED & PRIMED & TOP COATED ANGLE. INSTALLED ANGLE & TOP COATED FASTENERS IAW SRM 51-40-21, 51-21-10, 53-15-13 & 51-75-10. REPAIR CLASSIFIED AS CAT A MAJOR REPAIR.