What was found
AFT CARGO UNDER THE FLOOR BILGE AREA SKIN STRINGER 29L CORRODED AT STATION 1460. REMOVED CORROSION IAW SRM 51-10- 02. NO ALLOWED DAMAGE ON SRM. R & R STRINGER SPLICED IAW SRM 51-40-02. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO UNDER THE FLOOR BILGE AREA SKIN STRINGER 29L CORRODED AT STATION 1460. REMOVED CORROSION IAW SRM 51-10- 02. NO ALLOWED DAMAGE ON SRM. R & R STRINGER SPLICED IAW SRM 51-40-02. MAJOR REPAIR.