What was found
AFT PIT STATION 1480 STRINGER 26R FRAME IS CORRODED ON FWD SIDE. REMOVED CORROSION IAW SRM 51-10-02. BLENDED AREA ORIG MATERIAL .063 MATERIAL REMAINING .055 D=.008 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07 FIG 101 DETAIL II. R & R FRAME STATION 1480 STRINGER 23L TO 23R BATCH 0002690754 PN 146N1030-76 IAW SRM 51-40-02 & DWG 146N1015. MAJOR REPAIR.