What was found
BS 960 - 984 RT CREASE BEAM WEB FOUND CORRODED. CORROSION REMOVED IAW SRM 51-10-02 REV 112. REWORKED AREA EVALUATED AND FOUND MATERIAL LOSS OF 0.021" OUT OF 10% LIMIT OF ORIGINAL THICKNESS OF 0.063" IAW SRM 53-40-13 ALLOWABLE DAMAGE 1 FIG 101 REV 113 DETAIL III. FABRICATED IAW DWG 144N5140 SHT 3 REV D. CREASE BEAM REMOVED AND REPLACED IAW SRM 51-40-02 REV 113 AND BOEING DWG 144N5140 SHT 3 REV D. REPAIR CLASSIFIED AS MAJOR.