What was found
BS 377.7 LBL 55 - 60 FLOORBEAM UPPER TEE FOUND CORROED ON LOWER SURFACE. FLOORBEAM TEE REMOVED AND REPLACED IAW DWG 141N5113 SHT 1 REV F. DWG 141N5123 SHT 1 REV A AND EA F-5310-T0311051 PART 1. REPAIR CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 377.7 LBL 55 - 60 FLOORBEAM UPPER TEE FOUND CORROED ON LOWER SURFACE. FLOORBEAM TEE REMOVED AND REPLACED IAW DWG 141N5113 SHT 1 REV F. DWG 141N5123 SHT 1 REV A AND EA F-5310-T0311051 PART 1. REPAIR CLASSIFIED AS MAJOR.