What was found
NR 3 LT PLUG DOOR JAMB CUT OUT AREA LOWER FWD WEB FOUND CRACKED. REPAIRED IAW SRM 53-40-15, FIGURE 201, REPAIR 3. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 3 LT PLUG DOOR JAMB CUT OUT AREA LOWER FWD WEB FOUND CRACKED. REPAIRED IAW SRM 53-40-15, FIGURE 201, REPAIR 3. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.