What was found
AT STATION 1675 - 1695 RT SIDE A CRACK WAS FOUND IN STRINGER 18 WHILE INSTALLING FLOORBEAM. R & R PN FX146N3820-89 FABRICATED ON T14 1089757 IAW SRM 51-40-02 & DWG 146N3820, STINGER SECTION. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT STATION 1675 - 1695 RT SIDE A CRACK WAS FOUND IN STRINGER 18 WHILE INSTALLING FLOORBEAM. R & R PN FX146N3820-89 FABRICATED ON T14 1089757 IAW SRM 51-40-02 & DWG 146N3820, STINGER SECTION. MAJOR REPAIR.