As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CLIMB OUT GOT EICAS RT ENG OVERHEAT. REFERENCE QRH. WHEN THROTTLE WAS RETARDED THROUGH 1.30 EPR, LIGHT WENT OUT WITH BLEED OFF. THIS WAS THE RT ENG. LIGHT REMAINED OFF THE REMAINDER OF FLIGHT. RETURNED TO BASE. R & R HP 2 DUCT ASSEMBLY 2 PC WITH NEW SEALS & CLAMPS. R & R HP 6 DUCT WITH NEW SEAL & CLAMP. PERFORMED ENG POWER RUN AT 1.35 EPR FOR 35 MIN IAW JRH NO FAULTS DURING RUN.