What was found
EMPENNAGE RT SIDE THE APU INLET STRUCTURE FROM BS 1790 - 1825 ALONG STRINGER 6 HAS CORROSION. FOUND OUT OF LIMIT IAW SRM 51-10-02 REV 113. CORRODED SUPPORT REMOVED AND REPLACED IAW DWG 148N3105 SHT 1 REV C. REPAIR CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMPENNAGE RT SIDE THE APU INLET STRUCTURE FROM BS 1790 - 1825 ALONG STRINGER 6 HAS CORROSION. FOUND OUT OF LIMIT IAW SRM 51-10-02 REV 113. CORRODED SUPPORT REMOVED AND REPLACED IAW DWG 148N3105 SHT 1 REV C. REPAIR CLASSIFIED AS MAJOR.