What was found
THERE ARE GOUGES ON THE EXISTING REPAIR ON FRAME AT BS 1520, STRINGER 24 - 25R. REMOVED & NEW FRAME SPLICE FABRICATED IAW DWG 146N1042 SHT 01 REV A . INSTALLED IAW DWG 146N1017 SHT 3 REV D. REPAIR CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THERE ARE GOUGES ON THE EXISTING REPAIR ON FRAME AT BS 1520, STRINGER 24 - 25R. REMOVED & NEW FRAME SPLICE FABRICATED IAW DWG 146N1042 SHT 01 REV A . INSTALLED IAW DWG 146N1017 SHT 3 REV D. REPAIR CLASSIFIED AS MAJOR.