As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FUSELAGE FRAME 47 SPLICE FITTING BETWEEN STRINGER 24 - 26 LT, INSPECTION FOUND FASTENER HOLE B WITH CRACK SIGNAL. COMPLIED WITH EA 6-5310-T0315451 PT1. REPAIRED FUSELAGE FRAME 47 SPLICE FITTING BETWEEN STGR24-26 LT, FASTENER HOLE "B". THIS REPAIR IS CATEGORY B. MAJOR REPAIR IAW GMM 6-2-100