What was found
DUE TO SLAT REMOVED FOR WORK ACCESS. RT WING NR 7 SLAT OTBD RIB FWD HOLE SPOT FACE FOUND WORN. BUSHING AT RIGHT HAND WING NR 7 SLAT OUTBOARD RIB FORWARD HOLE BORE REMOVED AS PER MD11 CMM 20-10-7 HOLE MEASURED DIA.: 0.875 INCH, AND FOUND WITHIN LIMIT AS PER SRM 57-40-02-2R FIGURE 201 REPAIR 10 NEW BUSHING INSTALLED WITH WET PRIMER AS PER SRM 57-40-02-2R FIGURE 201 REPAIR 10 AND EA 1-5750-T0316077 PART 1 STEP 2 TITLE: "WINGS -FLIGHT SURFACES - RT WING - NR 7 SLAT ASSY - SRM REPAIR - RSC TRACKING " REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100 REFER TO WRI 57502062 FOR WORK DETAILS