What was found
DUE TO SLAT REMOVED FOR WORK ACCESS, RT HAND WING NR 7 SLAT OTBD RIB FWD HOLE BORE FOUND WORN. RT HAND WING NR 7 SLAT OUTBOARD RIB FORWARD HOLE SPOTFACE REWORKED AND FOUND WITHIN LIMIT AS PER SRM 57-40-02-2R FIGURE 201 REPAIR 10 AND EA 1-5750-T0316077 PART 1 STEP 2. EXISTING THICKNESS: 0.392 INCH, MATERIAL REMOVED: 0.022 INCH, REMAINING THICKNESS: 0.370 INCH, MINIMUM ALLOWABLE: 0.340 INCH REPAIR ACCOMPLISHED AS PER EA 1-5750-T0316077 PART 1 TITLE: WINGS - FLIGHT SURFACES - RT WING - NR 7 SLAT ASSY - SRM REPAIR - RSC TRACKING " REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100.