What was found
FLOOR PANEL SUPPORT LAND FOUND CORRODED, AFT INTERMEDIATE SECTION FUSELAGE STATION 1986, APPROX LBL 2. R & R FLOOR SUPPORT IAW DWG AGA 7091. INSTALLED IAW SRM CHAPTER 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR PANEL SUPPORT LAND FOUND CORRODED, AFT INTERMEDIATE SECTION FUSELAGE STATION 1986, APPROX LBL 2. R & R FLOOR SUPPORT IAW DWG AGA 7091. INSTALLED IAW SRM CHAPTER 51-31-01.