What was found
NUMBER 1 ENG PYLON FWD MOUNT FITTING, PYRAMID, FWD HOLES & ALIGNMENT HOLE UPPER SURFACE AREA LIGHT SURFACE CORROSION. REPAIRED FWD MOUNT FWD HOLE IAW SRM 54-51-81 FIG 202. CLEANED ALIGNMENT HOLE UPPER SURFACE IAW SRM 54-51-81. FOUND TO BE SEALANT & DIRT ONLY, NO MATERIAL. LOSS NOTED TREATED & PRIMED AREA IAW SRM 54-51-81 CLASS A MAJOR REPAIR.