As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK LT FRAME 58, IS GOUGED OVERHEAD STRINGER 13L. GOUGE DEPTH EQUALS .048, FOUND TO BE OUT OF LIMITS IAW SRM-53-10-13. CUT OUT DAMAGE L=.700" W=.600" IAW SRM-53-10-13 FIG 22. REPAIR ANGLE FABRICATED ON T15 1136703. INSTALLED REPAIR ANGLE IAW-SRM-51-40-21 & SRM-53-10-13 FIG 202. TREATED & PRIMED REPAIR ANGLE IAW-SRM-51-21-10. REPAIR CLASSIFIED AS CAT B MAJOR REPAIR.