What was found
AGEING ACFT, EXISTING REPAIR ON FRAME AT MAIN CARGO COMPARTMENT STATION 1661, LONGERON 12L. EXISTING REPAIR EVALUATED & FOUND DAMAGED. R & R WITH NEW REPAIR IAW SRM 53-00-07-2R REPAIR 2 FIGURE 201, EO 1-5100-7-5001 B5 PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. INITIAL INSPECTION TO BE CARRIED OUT AFTER 14,000 CYCLES & REPETITIVE INSPECTION TO BE CARRIED OUT AT EVERY 9,500 CYCLES IAW SRM 53-00-07-2R REPAIR 2 TABLE 201.