What was found
AGEING ACFT, EXISTING REPAIR ON FRAME AT MAIN CARGO COMPARTMENT STATION 1741, LONGERON 12L. EXISTING REPAIR ON FRAME AT MAIN CARGO COMPARTMENT STATION 1741 LONGERON 12L. EVALUATED & FOUND DAMAGE. EXISTING REPAIR R & R IAW SRM 53-00-07-02R REPAIR 2 FIGURE 201. EO 1-5100-7-5001 B5 PART 1. INSPECTION TO BE CARRIED OUT AFTER 14,500 CYCLES & REPETITIVE INSPECTION TO BE CARRIED OUT AT EVERY 9,500 CYCLES BY HFEC IAW SRM 53-0-07-2R REPAIR 2 TABLE 201.