What was found
MAIN DECK FLOORBOARD 231YG UPPER SURFACE IS CRACKED. FABRICATED A NEW FLOORBOARD IAW DWG SRZ 25-00- REV L CLASIFIED AS CATAGORY "A" MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOORBOARD 231YG UPPER SURFACE IS CRACKED. FABRICATED A NEW FLOORBOARD IAW DWG SRZ 25-00- REV L CLASIFIED AS CATAGORY "A" MAJOR REPAIR.