What was found
MAIN CARGO DECK BETWEEN FRAME 57.1 & 58, -Y450 & -Y953 FLOORBOARD HAS CRACKS. R & R FLOOR PANEL 252 GF IAW AMM 53-10-23-04. NEW FLOOR PANEL FABRICATED ON T15 1147412 IAW DWG SRZ-25-005. CLASSIFIED CAT A MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CARGO DECK BETWEEN FRAME 57.1 & 58, -Y450 & -Y953 FLOORBOARD HAS CRACKS. R & R FLOOR PANEL 252 GF IAW AMM 53-10-23-04. NEW FLOOR PANEL FABRICATED ON T15 1147412 IAW DWG SRZ-25-005. CLASSIFIED CAT A MAJOR REPAIR.