What was found
LEFT OTBD FLAP, OTBD AFT HINGE PIVOT, OTBD HOLE BORE CORROSION. CORROSION REWORKED & FOUND EXCEEDED LIMIT IAW CMM 57-52-04. EXISTING 1.141 INCH, FINAL 1.152 INCH & MAXIMUM ALLOWABLE 1.150 INCH. REPAIR ACCOMPLISHED IAW EA 1- 5750-T0318605 PART 1. REFER TO WRI 57502077 FOR WORK DETAILS. REPAIR CLASSIFIED A MINOR IAW GMM 6-2-100.