What was found
PRIOR TO START OF LOADING, AMJ ON DOLLY STRUCK THE ACFT AT AREA APPROX 1 FOOT ABOVE & SLIGHTLY AHEAD OF LT STATIC PORT RED OUTLINE. NO RESTRICTION IAW 53-10-12 DENT WAS FOUND 1 FOOT ABOVE THE LT STATIC PORT RED OUTLINED AREA & IS WITHIN LIMITS IAW SRM 53-10-12 DIAGRAM 103 SHEET 1 FLAG NOTE 2 IAW ER 13-07745, EXTERNAL DVI USING 10X MAG GLASS CARRIED OUT OF DENT LOCATION WITH NO CRACKS FOUND, NO SKIN GOUGES, DENT AREA COVERED WITH SPEED TAPE FOR PROTECTION. REPAIRED DAMAGED SKIN IAW SRM 53-10-12 FIGURE 207 SHEET 5. REPAIRED DAMAGED SKIN IAW SRM 53-10-12 FIG 202 SH 5.