What was found
LEFT WING, WING SIDE OTBD FLAP HINGE, LOWER MOUNT INBD HOLE BORE FOUND CORROSIONS. CORROSION REWORKED & FOUND EXCEEDS LIMIT IAW CMM 57-44-09. EXISTING HOLE DIAMETER =0.591", FINAL HOLE DIAMETER =0.599", MAXIMUM ALLOWABLE HOLE DIAMETER =0.584". AIR BUSHING FABRICATED BY MACHINING & INSTALLED IAW EA 1-5750-T0319446 PART 1 STEP 1A. CORROSION REPAIRED. REPAIR CLASSIFIED MINOR IAW GMM 6-2-100. REFER TO WRI 57501279 FOR WORK DETAILS.