What was found
MAIN DECK FLOORBEAM AT BS 1661 RBL 56, HAS CORROSION AROUND FASTENER HOLE. REMOVED CORROSION IAW SRM 51-10-02. CHECKED LIMITS & FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51-1A FIG 101 DETAIL III. R & R FLOORBEAM IAW SRM 51-40-02 & DWG 146N5090. MAJOR REPAIR.