What was found
AFT PIT SIDEWALL LT SIDE FRAME, INNER CHORD CORRODED AT STATION 1420 BETWEEN STRINGER 19L & 18L. R & R FRAME, INNER CHORD AT STATION 1420, STRINGER 18L - 22L IAW SRM 51-40-02 & DWG 146N1012. REMOVED CORROSION, FOUND OUT OF LIMITS IAW SRM 51-10-02, SRM 53-00-07-1A FIG 101 DET II. CATEGORY A REPAIR, MAJOR REPAIR.